Seite 1

i50 Scanneri60 ScannerUser’sGuideA-61182

Seite 2 - Contents

A-61182 October 2001 5InstallationUnpack the scanner carefully and check the contents. If any items are missing ordamaged, contact your authorized d

Seite 3

6 A-61182 October 2001Locking the scanner1. Make sure that the scanner is off.2. Raise the document cover to reveal the flatbed platen and scannin

Seite 4 - A-61182 October 2001 iii

A-61182 October 2001 7SCSI interface device IDWhen you have several devices on a SCSI chain, you may need to adjust the SCSIID selector on the scann

Seite 5

8 A-61182 October 2001Adjusting the traysThere are two trays on the scanner: the ADF tray for loading documents to be scannedthrough the automatic d

Seite 6 - Introduction

A-61182 October 2001 9Output tray1. Lift the output tray to about a 30° angle.2. Insert the three protrusions on the output tray into the three sl

Seite 7 - Acoustic emission

10 A-61182 October 2001Requirements and software installationTo operate the scanner at its optimum speed, the following minimum configuration isrequ

Seite 8 - For Japan

A-61182 October 2001 11Scanning your documentsLoading documentsMake sure that the scanner is on and has completed its self-test before you turn onth

Seite 9 - Scanning specifications

12 A-61182 October 2001Scanning withTWAIN or ISIS1. Open your scanning application.2. Choose Select Source or Select Scanner on the File menu.If th

Seite 10 - Installation

A-61182 October 2001 13Making the most of your scanned imagesThe features in the TWAIN and ISIS dialog boxes are described in this section.Note that

Seite 11 - Making connections

14 A-61182 October 2001Image TypeSelect the mode you want to use for your scans on the Image Type drop-down menu.Black and White—the image appears i

Seite 12 - Setting the SCSI

A-61182 October 2001 iContentsContents...

Seite 13 - Adjusting the trays

A-61182 October 2001 15ResolutionResolution or dots per inch (dpi) indicates the scanning resolution, which largelydetermines the quality of the sca

Seite 14 - Powering up the scanner

16 A-61182 October 2001BrightnessThis function allows you to adjust the image brightness, making it lighter or darker.You can adjust the brightness

Seite 15 - Installing the

A-61182 October 2001 17Enhancing your imagesThese features allow you to improve or enhance the appearance of scanned images.InvertClick on the Inver

Seite 16 - Scanning your documents

18 A-61182 October 2001DescreenClick on the Descreen button to access a drop-down menu that allows you to specifythe type of document you are scanni

Seite 17 - Scanning with

A-61182 October 2001 19Highlight / ShadowThis feature is available when 8-Bit Gray, 8-Bit Color, or 24-Bit Color is selected on theImage Type drop-d

Seite 18 - Scan Method

20 A-61182 October 2001CurvesWhen you select the Curves button, a dialog box appears that allows you to adjust themidtone of the image without losin

Seite 19 - Image Type

A-61182 October 2001 21Hue /Saturation /LightnessClick on this button to access a dialog box that allows you to adjust the hue,saturation, and light

Seite 20 - Resolution

22 A-61182 October 2001Color Drop-outThis feature is available when Black and White, Halftone, or 8-Bit Gray is selected onthe Image Type drop-down

Seite 21 - Contrast

A-61182 October 2001 23Custom SettingsClick on the Custom Settings button to access a dialog box where you can save yourscan settings and configurat

Seite 22 - Enhancing your images

24 A-61182 October 2001Configuration SettingsThe Configuration Settings tab allows you to customize some special settings.Energy Saving Mode—check t

Seite 23 - Advanced Settings

ii A-61182 October 2001Requirements and software installation... 10Installing the scanner drive

Seite 24 - Highlight / Shadow

A-61182 October 2001 25Other toolsIn addition to the image enhancement options, the dialog box contains the itemsdescribed below.WidthShows the curr

Seite 25 - Color Balance

26 A-61182 October 2001Starting the final scanThe buttons shown below allow you to begin scanning or to exit the job.PreviewClick on the Preview but

Seite 26 - Lightness

A-61182 October 2001 27MaintenanceThe scanner is designed to be maintenance free. However, it must be cleanedoccasionally to ensure optimum image qu

Seite 27 - Color Drop-out

28 A-61182 October 2001Cleaning the ADFThe ADF feed module and the feed rollers may become contaminated with ink, toner,and paper dust. If the scann

Seite 28 - Custom Settings

A-61182 October 2001 29Replacing the ADFsnap-in feed moduleAfter approximately 100,000 pages have been scanned through the ADF, the separation pad m

Seite 29

30 A-61182 October 2001TroubleshootingThe scanner automatically performs a simple self-test each time it is powered up.This helps spot major system

Seite 30 - Other tools

A-61182 October 2001 31Problem SolutionWhen the scanner is powered up, the lampdoes not light.• The lamp is dead. Contact your dealer to change the

Seite 31 - Starting the final scan

32 A-61182 October 2001Getting serviceIf you believe that your scanner needs service, go to www.kodak.com/go/docimaging.There you can find out how b

Seite 32 - Maintenance

A-61182 October 2001 33 Specifications Scanner type i50 Scanner: ADF/flatbed desktop simplex color scanner i60 Scanner: ADF/flatbed desktop dupl

Seite 33 - Cleaning the ADF

EASTMAN KODAK COMPANYDocument ImagingRochester, New York 14650www.kodak.com/go/docimagingKodak is a trademark ofEastman Kodak Company.A-61182 10/200

Seite 34 - Replacing the ADF

A-61182 October 2001 iii Color Adjustment... 18 Auto Level ...

Seite 35 - Troubleshooting

iv A-61182 October 2001Maintenance... 27Cleaning

Seite 36

A-61182 October 2001 1IntroductionThank you for purchasing a KODAK scanner.• The KODAK i50 Scanner is a desktop simplex color scanner.• The KODAK

Seite 37 - Scanner supplies

2 A-61182 October 2001Safety• Use only the power supply that was provided with the scanner (Sino-Americanmodel SA60-24).IMPORTANT: Do not substitut

Seite 38 - Specifications

A-61182 October 2001 3Electromagnetic compliance statementsFor the United StatesThis equipment has been tested and found to comply with the limits f

Seite 39 - DOCUMENT

4 A-61182 October 2001Scanning specificationsAcceptable paper sizesYou can use the i50 Scanner and i60 Scanner to scan documents that have a paperwe